MIRTEK-12-EN-D5

Single-phase multifunctional electricity meter of model MIRTEK-12-EN-D5

The device provides for the metering of the:

  • current time and date;
  • electrical energy quantity on a cumulative total independent of the tariff schedule;
  • electrical energy quantity on a cumulative total and separately by the current tariffs rates;
  • electrical energy quantity on a cumulative total and separately by the current tariffs rates at the beginning of the month;
  • electrical energy quantity on a cumulative total and separately by the current tariffs rates at the beginning of the day;
  • power profile averaged in the 30 minutes interval (or from the following range: 1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30, 60 minutes);
  • electrical energy quantity on a cumulative total and separately by the current tariffs rates at the beginning of the 30 or 60 minutes interval (stated interval of averaging power is 30 or 60 minutes);
  • electrical energy quantity consumed within 30 minutes interval (stated interval of averaging power is 30 minutes).

Technical specification

Accuracy class according to GOST 31819.21-2012

1

Nominal voltage

220 V or 230 V

Voltage supply range

from 0.75 Unom to 1.2 Unom

Measuring network frequency

(50±7,5) Hz

Base (nominal) current

5 А

Maximum current

50 А, 60 А, 80 А

Value range of meter constant for active electricity energy

from 800 to 10000 imp / (kW · h)

Starting current

12,5 мА

Total (active) power, consumed by meter voltage circuit, at nominal voltage, nominal temperature, nominal frequency is not higher than

10V · A (2W)

The total power consumed by each current circuit, at the base current, normal temperature and nominal frequency of the network is not higher than

0.3 V · A

Operating temperature range

from -40 to +70 °С

Calibration interval

16 years

Service life, no less

30 years

Mean time to failure, no less

220000 h

Type designation

MIRTEK-12-EN - D5 - XXXX - XXX - XX - XXX - XX - XXXXXX - XXXX - XX - XXXXXXXX - X

Meter type

Case type

D5 – for installation on a DIN-rail, modification 5

Accuracy class

A1 – accuracy class 1 according to GOST 31819.21

Nominal voltage

220 – 220 V
230 – 230 V

Base current

5 – 5 А

Maximum current

50 – 50 А
60 – 60 А
80 – 80 А

Quantity and measuring elements type

S – one shunt in phase current circuit

The first interface

RS485 – interface RS-485

The second interface

(No symbol) – no interface

Supported protocols of data communication

(No symbol) – protocol «MIRTEK»

Additional functions

H – magnetic field sensor
O – optical port
Qn – discrete output, where n – outputs quantity (from 1 to 4)
R – protection against unscrewing of the cover screws
U – protection of the case continuity
Vn – electronic seal, where n can take values:
  1. electronic seal on the case
  2. electronic seal on the terminal cover
  3. electronic seals on the case and terminal cover
(No symbol) – no additional functions

Directions quantity of the electricity metering

(No symbol) – electricity metering in one direction (in module)

Overall and mounting dimensions